Lamp For Still | FMB / Union / Realstar 0305007 is a lamp or bulb used in compatible FMB / Firbimatic, Union, and Realstar dry-cleaning machine service for Electrical / controls work.
Use this listing when the installed lamp or bulb, machine manual, service record, or component label matches 0305007, E16705. Before ordering, compare model marking, voltage, contact or pin arrangement, terminal layout, mounting, and installed control circuit.
Technical Specifications
Component type: lamp or bulb.
Primary system: Electrical / controls.
Primary identifiers: 0305007, E16705.
Legacy / old reference: E16705.
Corbett evidence note: Lamp For Still Dry Cleaning Part 0305007..
Corbett evidence note: Component type: Lamp / electrical...
Corbett evidence note: Lamp For Still Dry Cleaning Part 0305007...
Verification points: model marking, voltage, contact or pin arrangement, terminal layout, mounting, and installed control circuit.
Part Numbers & Cross References
Part Numbers
Corbett / manufacturer reference: 0305007.
Corbett / manufacturer reference: E16705.
Cross References
Legacy / old reference: E16705.
Evidence note: Still Bulb 24V 25W (Old #E16705)...
Evidence note: Still Bulb (Old #E16705)...
Machine Fitment
Machine fitment for Lamp For Still | FMB / Union / Realstar 0305007 is organized through Corbett Equipment master manufacturer and model-lineage evidence. Use this section as a fitment-reference map, then verify the installed component, machine data plate, service manual, dimensions, voltage or pressure ratings where applicable, mounting, fittings, and part-number path before ordering.
Master manufacturer / model lineage
Corbett Equipment and FXT Factory records treat FMB / Firbimatic as the master machine-model lineage for this catalog family. Union, Realstar, and Sovrana references are derivative-reference families that must be matched through the installed component, manual table, and machine-specific service record.
FMB / Firbimatic machine models and master families
EcoPro / ECOPRO family: ECOPRO 915, ECOPRO 915S, ECOPRO 918, ECOPRO 918S, ECOPRO AM, ECOPRO AM918.
Saver family: SAVER 35, SAVER 350, SAVER 35P, SAVER 350P, SAVER 40, SAVER 40P, SAVER 80SM, SAVER HYDROCARBON.
F-series / 18 kg family: F AS 18 LT2, F AS 18 ST2, F18 LT2, F18 LT3, F18 ST2.
EcoGreen family: EcoGreen 35, EcoGreen 40 / L2118, EcoGreen 50 / L2120, EcoGreen 60 / L2125, EcoGreen 80 / L2132, EcoGreen 95, EcoGreen 95SM, EcoGreen DC, EcoGreen S50 / S2120, EcoGreen Advance.
EcoGreen SM / AM-prefix soft-mount family: AM918, AM925, AM940, AM2118, S2118, EcoGreen 40SM, EcoGreen 60SM, EcoPro 40SM, EcoPro 60SM.
EcoLine family: EcoLine 35, ECOLINE, ECOLINE 16.
Vortex family: VORTEX 40, VORTEX 50, VORTEX 80, VORTEX 95, VORTEX L2018, VORTEX S2018, VORTEX PRIMARY, Vortex 40 Plus, Vortex 50 Plus, Vortex 80 Plus, Vortex 50 Plus Tandem.
Axial family: AXIAL 40, AXIAL 918, AXIAL 925, AXIAL-918.
System and feature lineage: Hydro-Vac, Hydro-Chill, Tri-Flow, Smart-10, SecureLock, and related recovery, filtration, distillation, cooling, and control-system records.
Other recovered FMB reference families: Eco-15LT3, Eco-15LT-3, L 18, L-250, L750, L2118, P16, P1567, P1705, P6241, T1838.
Recovered numeric model set: 035, 05, 068, 08, 09, 10, 100, 12, 120, 13, 130, 14, 15, 153, 16, 20, 208, 220, 23, 24, 25, 30, 306, 310, 32, 338, 340, 35, 36, 37, 40, 410, 45, 465, 473, 50, 520, 60, 600, 63, 70, 71, 724, 765, 80, 895, 896, 918, 95.
Factory/model-code references observed in recovered Corbett lineage records: HC7-18-CL, HC7-18-CLM, HC7-18-CS, HC8-18-CL, HC8-18-CLM, HC8-18-CS.
Union machine models and derivative families
Core Union derivative references: HXP8018C, L840, P840.
HL / HP / HXL family references: HL-780, HL780, HL-840, HL840K, HP840K, HXL8018K, HL-850, HL850K, HP850K, HL-860, HL860K, HP860K, HXL8025K, HL-880, HL880K, HXL8032K, HL-890, HL890K.
L / RS family references: L740S, L740, HL740, L750, RS-102, RS-122, RS-152.
Verify Union fitment by matching the installed part, Union manual table, FMB / Firbimatic master-model relationship, connection details, and service location.
Realstar machine models and derivative families
KM / KT derivative references: KM315, KM315-K4, KT215, KT215-K4, KM343, KM343-K4, KT343, KT343-K4.
Larger KM / KT references: KM403, KM403-K4, KT403, KT403-K4, KM503, KM503-K4, KT503, KM703, KM703-K4, KM803, KM803-K4.
RKM references: KM-36 / RKM36, KM-340 / RKM340, KM-400 / RKM400.
Verify Realstar fitment by matching the installed part, Realstar manual table, FMB / Firbimatic master-model relationship, connection details, and service location.
Sovrana and other derivative references
Sovrana and other derivative-model references may appear in Corbett lineage records. Treat them as research clues only unless the installed component, machine manual, and part-number path confirm the application.
EcoGreen S-Series Applications
Electric-still assembly 0728.2 with matching 0305007 still-viewing lamp/holder arrangement; verify bulb electrical rating and installed fitting before ordering. Confirm exact machine model, serial/revision and installed component before ordering. Listed sister-model applications are conditional on the matching assembly and component configuration.
FMB / Firbimatic: EcoGreen Petite 50 (20 kg); S2120 (20 kg).
Union (matching component and configuration required): HL850 (20 kg); HL850-K (20 kg); HP850 (20 kg); HP850-K (20 kg).
Realstar (matching component and configuration required): KM403 (20 kg); KM403-K4 (20 kg); KT403 (20 kg).
Additional Numeric-Model Applications
For the matching installed component in the listed legacy numeric-model configuration. Match the installed still inspection lamp, voltage, holder, connection and sealing arrangement. Confirm the exact machine data plate, serial/revision and installed assembly before ordering. Numeric model designations are retained as printed; capacity or a similar commercial model name alone does not establish compatibility.
FMB / Firbimatic: 918S, 912S-L, 915S-L, 918LT3. Match the installed still inspection lamp, voltage, holder, connection and sealing arrangement.
Additional Configuration-Specific Applications
Match the installed still inspection lamp, voltage, holder, connection and sealing arrangement. These applications require the exact matching installed component and assembly configuration. Confirm machine data plate, serial/revision, ratings, dimensions and connections before ordering; model name or capacity alone is not sufficient.
FMB / Firbimatic — configuration-qualified: VORTEX S2020 (20 kg). Match the installed still inspection lamp, voltage, holder, connection and sealing arrangement. Application requires the matching installed assembly, component markings and machine serial/revision represented by the model-specific parts manual.
Ordering Verification
Confirm 0305007, E16705 before ordering.
Compare model marking, voltage, contact or pin arrangement, terminal layout, mounting, and installed control circuit against the installed component.
Inspect the mating parts, wiring, fittings, sealing surfaces, or mounting hardware before installation.
After installation, verify correct machine operation and leak-free or electrically safe service before returning equipment to use.